Cyky-J, O, Power/Control Cable, 450/750 V, Cu/PVC/PVC (CSN 347656, CSN 347615)

Model NO.: CYKY-J, O
Material Shape: Round Wire
Range of Application: Installation
Certification: ISO9001, CCC
Brand: Boan
Rated Voltage: 450/750 V
Size Range: 25-240 Mm2
Class of Conductor: 1
Number of Cores: 2-37
Trademark: DingAn or OEM
Specification: SGS
Origin: Jiangsu Yixing, China
HS Code: 8544492100
Model NO.: CYKY-J, O
Material Shape: Round Wire
Range of Application: Installation
Certification: ISO9001, CCC
Brand: Boan
Rated Voltage: 450/750 V
Size Range: 25-240 Mm2
Class of Conductor: 1
Number of Cores: 2-37
Trademark: DingAn or OEM
Specification: SGS
Origin: Jiangsu Yixing, China
HS Code: 8544492100
CYKY-J, O 450/750V
PVC insulated and PVC sheathed power and control cable

Usage:
For fixed installation in interior premises, cable ducts, in the open air, in water as permitted by the local building regulations if no risk of any mechanical damage is to be expected

Construction:
1 Copper conductor, round solid (RE), round stranded (RM) resp. Sector-shaped stranded (SM)
2 Core insulation (PVC)
3 Inner covering (EPDM or plastic tape)
4 Sheath (PVC black, UV-resistant)

Rated voltage: 450/750 V
Working temperature: -15° C + 70° C
Lowest installation temperature: -5 ° C
Maximum short-circuit conductor temperature: +160oC

Bending radius (min. ): 10 x of cable
Flame retardant: EN 60332-1-2
Number and cross-sectional area of conductor Approximate overall diameter Approximate net weight of cables Maximum conductor resistance at temperature 20
n x mm2 mm kg/km Ω/km
2x1,5 7,2 90 12,1
2x2,5 8,0 119 7,41
2x4 9,7 180 4,61
3x1,5 7,6 106 12,1
3x2,5 8,5 144 7,41
3x4 10,3 220 4,61
3x6 12,1 312 3,08
4x1,5 8,3 129 12,1
4x2,5 9,2 176 7,41
4x4 11,7 281 4,61
4x6 13,2 384 3,08
4x10 15,1 565 1,83
4x16 17,7 833 1,15
5x1,5 9,1 157 12,1
5x2,5 10,1 215 7,41
5x4 12,8 345 4,61
5x6 14,5 471 3,08
5x10 17,0 712 1,83
5x16 19,4 1030 1,15
7x1,5 10,2 204 12,1
7x2,5 11,7 293 7,41
12x1,5 13,7 341 12,1
12x2,5 15,2 474 7,41
19x1,5 15,9 493 12,1
19x2,5 18,2 712 7,41
24x1,5 19,0 637 12,1
24x2,5 21,2 895 7,41
37x1,5 21,6 909 12,1

CYKY-J, O 450/750V
PVC insulated and PVC sheathed power and control cable

Usage:
For fixed installation in interior premises, cable ducts, in the open air, in water as permitted by the local building regulations if no risk of any mechanical damage is to be expected

Construction:
1 Copper conductor, round solid (RE), round stranded (RM) resp. Sector-shaped stranded (SM)
2 Core insulation (PVC)
3 Inner covering (EPDM or plastic tape)
4 Sheath (PVC black, UV-resistant)

Rated voltage: 450/750 V
Working temperature: -15° C + 70° C
Lowest installation temperature: -5 ° C
Maximum short-circuit conductor temperature: +160oC

Bending radius (min. ): 10 x of cable
Flame retardant: EN 60332-1-2
Number and cross-sectional area of conductor Approximate overall diameter Approximate net weight of cables Maximum conductor resistance at temperature 20
n x mm2 mm kg/km Ω/km
2x1,5 7,2 90 12,1
2x2,5 8,0 119 7,41
2x4 9,7 180 4,61
3x1,5 7,6 106 12,1
3x2,5 8,5 144 7,41
3x4 10,3 220 4,61
3x6 12,1 312 3,08
4x1,5 8,3 129 12,1
4x2,5 9,2 176 7,41
4x4 11,7 281 4,61
4x6 13,2 384 3,08
4x10 15,1 565 1,83
4x16 17,7 833 1,15
5x1,5 9,1 157 12,1
5x2,5 10,1 215 7,41
5x4 12,8 345 4,61
5x6 14,5 471 3,08
5x10 17,0 712 1,83
5x16 19,4 1030 1,15
7x1,5 10,2 204 12,1
7x2,5 11,7 293 7,41
12x1,5 13,7 341 12,1
12x2,5 15,2 474 7,41
19x1,5 15,9 493 12,1
19x2,5 18,2 712 7,41
24x1,5 19,0 637 12,1
24x2,5 21,2 895 7,41
37x1,5 21,6 909 12,1

HPS&MH Flood Light