Hot Selling Product 21/35kv Aluminium Conductor XLPE Insulated Unarmoured Power Cable

Model NO.: YJV
Wire Core Material: Bare Copper Wire
Certification: ISO, CCC, CE, RoHS, UL, VDE
Model: YJV
Brand: Jinshui
Trademark: JINSHUI
Transport Package: Wooden Drun
Specification: YJV
Origin: China
HS Code: 8544492100
Model NO.: YJV
Wire Core Material: Bare Copper Wire
Certification: ISO, CCC, CE, RoHS, UL, VDE
Model: YJV
Brand: Jinshui
Trademark: JINSHUI
Transport Package: Wooden Drun
Specification: YJV
Origin: China
HS Code: 8544492100

Cu/XLPE/SWA/PVC Power Cable YJV22

Al/Cu Conductor XLPE Insulated Thin/Thick steel armored PE Sheathed Power Cable.

Executive Standard: 


It is manufacture under GB/T12706-2002 standard(The same as IEC60502). 

Application: 

It is used to transmit and distribute power in power transmission and distribution system of 35kV or lower. 
It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and 
communication in complete replace of oil immersed paper insulated power cable and in partial replace of PVC
 insulated power cable. 

Using features: 

1. Rated voltage: Uo/U: 26/35kV, 21/35kV, 12/20 kV (24 kV), 8.7/10kV, 8.7/15kV, 6/6kV, 6/10kV. 

2. No. of core: Single-core, Three-core. 

3. The highest allowed operating temperature of conductor for long-term working is 90oC. In short-circuit (Max. Long-term is no more than 5 seconds). The highest temperature for conductor is no more than 250. 

4. D.C Resistance of the conductor complies with the stipulations of GB/T3956-1997. 

5. The environment temperature should be no lower than 0 when lay. Otherwise it should be preheated. 

6. The cable is laid without horizontal drop limit. The Min. Bending radius of three-core cable should be no smaller than 12 times of cable outer diameter. 

7. Working Frequency Voltage Test:. 

For cable with Uo of 3.6kV or lower: 2.5Uo+2kV/5min without puncture. 
For cable with Uo of 3.6kv~18kV: 3.5Uo/5min without puncture. 
For cable with Uo of 21kV and 26 kV: 2.5Uo/30min without puncture. 

8. Partial Discharge Test: The discharge volume should be no more than 10pC under 1.73Uo for the cable.
 
This series includes:
 
Copper (aluminum) core, XLPE insulated and sheathed power cables. 

Copper (aluminum) core, XLPE insulated, PE sheathed power cables. 

Copper (aluminum) core, XLPE insulated, steel tape armoring PVC sheathed power cables. 

Copper (aluminum) core, XLPE insulated, steel tape armoring, PE sheathed power cables. 

Copper (aluminum) core, XLPE insulated, steel wire armoring, PVC sheathed power Cables. 

Copper (aluminum) core, XLPE insulated, steel wire armoring, PE sheathed power cables 
Hot Selling Product 21/35kv Aluminium Conductor XLPE Insulated Unarmoured Power Cable
Hot Selling Product 21/35kv Aluminium Conductor XLPE Insulated Unarmoured Power Cable


 

Cu/XLPE/SWA/PVC Power Cable YJV22

Al/Cu Conductor XLPE Insulated Thin/Thick steel armored PE Sheathed Power Cable.

Executive Standard: 


It is manufacture under GB/T12706-2002 standard(The same as IEC60502). 

Application: 

It is used to transmit and distribute power in power transmission and distribution system of 35kV or lower. 
It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and 
communication in complete replace of oil immersed paper insulated power cable and in partial replace of PVC
 insulated power cable. 

Using features: 

1. Rated voltage: Uo/U: 26/35kV, 21/35kV, 12/20 kV (24 kV), 8.7/10kV, 8.7/15kV, 6/6kV, 6/10kV. 

2. No. of core: Single-core, Three-core. 

3. The highest allowed operating temperature of conductor for long-term working is 90oC. In short-circuit (Max. Long-term is no more than 5 seconds). The highest temperature for conductor is no more than 250. 

4. D.C Resistance of the conductor complies with the stipulations of GB/T3956-1997. 

5. The environment temperature should be no lower than 0 when lay. Otherwise it should be preheated. 

6. The cable is laid without horizontal drop limit. The Min. Bending radius of three-core cable should be no smaller than 12 times of cable outer diameter. 

7. Working Frequency Voltage Test:. 

For cable with Uo of 3.6kV or lower: 2.5Uo+2kV/5min without puncture. 
For cable with Uo of 3.6kv~18kV: 3.5Uo/5min without puncture. 
For cable with Uo of 21kV and 26 kV: 2.5Uo/30min without puncture. 

8. Partial Discharge Test: The discharge volume should be no more than 10pC under 1.73Uo for the cable.
 
This series includes:
 
Copper (aluminum) core, XLPE insulated and sheathed power cables. 

Copper (aluminum) core, XLPE insulated, PE sheathed power cables. 

Copper (aluminum) core, XLPE insulated, steel tape armoring PVC sheathed power cables. 

Copper (aluminum) core, XLPE insulated, steel tape armoring, PE sheathed power cables. 

Copper (aluminum) core, XLPE insulated, steel wire armoring, PVC sheathed power Cables. 

Copper (aluminum) core, XLPE insulated, steel wire armoring, PE sheathed power cables 
Hot Selling Product 21/35kv Aluminium Conductor XLPE Insulated Unarmoured Power Cable
Hot Selling Product 21/35kv Aluminium Conductor XLPE Insulated Unarmoured Power Cable


 

LED Linear Highbay Light

LED Linear Highbay Light,LED Gas Station Canopy Light,LED Outdoor Wall Lights ,LED Wall Pack Lights

LED Light Co., Ltd. , http://www.nblellight.com

Posted on