How to use the network cable tester _ network cable tester use method

Nowadays, cables are used in all aspects of people's production and life. Therefore, mastering the operation method of the network cable tester is the most basic requirement of the most cable users. How to use the network cable tester?

How to use the computer network cable tester

1. Insert the two ends of the network cable above the main auxiliary test line, and insert any head at will;

2, then open the switch of the line meter;

3. Observe that the indicators of 1-8 on the main and auxiliary line tester are not lit, and the order of the lights is correct.

4. For example, if the 1 light on the main line meter is on, the 1 light on the auxiliary line meter should also be on. If the 1 light on the main line meter is on, and the 2 lights on the auxiliary line meter are on, it means that the network cable is faulty and cannot be used normally.

5, 8 lights, as long as 1, 2, 3, 6 lights, the network cable can be used, because the data is transmitted through the four lines, the other four lines are not used to transmit data.

There are two criteria for the order of the network cable:

1: T568-B standard, the order is orange white, orange, green white, blue, blue white, green, brown white, brown.

2: T568-A standard, the order is green white, green, orange white, blue, blue white, orange, brown white, brown.

The first standard is generally used.

Second, insert the crystal heads at both ends of the network cable into the RJ45 port of the main tester and the remote test terminal, and turn the switch to “ON” (S is the slow gear). At this time, the indicator head of the main tester and the remote test end should flash one by one. bright.

Straight-through connection test: When testing the straight-through connection, the indicator of the main tester should flash from 1 to 8 one by one, and the indicator of the remote test end should also flash from 1 to 8 one by one. If this is the case, it means that the connectivity of the straight-through line is no problem, otherwise it will have to be redone.

Test of staggered line connection: When testing the interleaved connection, the indicator of the main tester should also flash from 1 to 8 one by one, and the indicator of the remote test end should be according to 3, 6, 1, 4, 5, The order of 2, 7, and 8 shines one by one. If this is the case, there is no problem with interleaved connectivity, otherwise it will have to be redone.

If the line sequence at both ends of the network cable is incorrect, the indicators of the main tester will still flash from 1 to 8 one by one, except that the indicators on the remote test end will flash one by one in the order of the line numbers connected to the main test end. In other words, the remote test terminals cannot be flashed in the order of the above steps.

How to use the network cable tester _ network cable tester use method

Wire break test

When there are 1 to 6 wires open, the corresponding wire number indicators of the main tester and the remote test end are not bright, and other lights can still flash one by one.

When there are 7 or 8 wires broken, the indicators of the main tester and the remote test end are all off.

Wire short circuit test phenomenon

When there are two wires short-circuited, the indicator of the main tester will still flash one by one in the order from 1 to 8, and the corresponding indicators of the two short-circuit wires of the remote test terminal will be illuminated at the same time. Other indicators Still flashing one by one in the normal order.

When there are three or more wires short-circuited, the indicators of the main tester still flash from 1 to 8 one by one, and the corresponding indicators of all the short-circuit wires of the remote test end are not bright.